B – Options
DPN 402197 © TSS (International) Ltd Page 9 of 12
Connect the 350 System to the 440 System:
7. Use the 440-to-350 Link Cable (TSS P/N 601814) to connect the 8-way ‘Power/
Comms’ connector on the 440 PSU to the AUX OUTPUT port on the 350 SEP.
This link uses RS232 communications at 9600 baud.
Note that the connectors at each end of the cable are of a different design. You
cannot reverse the cable when you make this connection.
Refer to sub-section 4.1.2 in this Manual for instructions to care for and assemble
the sub-sea connectors. Make all interconnections between the sub-sea assem-
blies and tighten the locking collars by hand. Do not over tighten the sub-sea con-
nectors.
Connect the SDC to the umbilical cable:
8. Refer either to sub-section 4.2.2 of this Manual or to the 440 Manual for instruc-
tions to complete the connection using the selected communication method.
B.1.5.1 System Configuration
The DeepView for Windows software allows you to configure and control both Sys-
tems in a Dualtrack installation.
If you are installing Dualtrack operation as an upgrade to an existing 440 or 350 Sys-
tem:
Ensure your SDC is capable of running Microsoft Windows™ 2000 and the DeepView
for Windows software. Contact TSS (International) Ltd for advice if necessary.
In a Dualtrack System, the 440 SEP must communicate using RS232. If your 440 SEP
uses 2-wire or 4-wire communications, refer to sub-section 4.2.2.1 of this Manual and
set RS232 communications before you install the SEP on the ROV.
Follow the instructions in sub-section 5.1 of this Manual to install the software onto
your SDC.
To configure the Dualtrack System properly you must complete the following actions.
1. Use the DeepView for Windows System Configuration Wizard to configure the 440
and the 350 Systems correctly. Select Dualtrack for the SEP type. Refer to sub-
section 6.2.2 of this Manual for instructions to configure the 350 System. Refer to
the 440 Manual for instructions to configure that System.
IMPORTANT
You must select Dualtrack as the SEP type even if you intend to use only one of the
Systems during the survey.
2. Take care to enter all details completely and correctly. Set appropriate altimeter
offsets for the 440 and the 350 Systems.