350 Cable Survey System
DPN 402197 © TSS (International) Ltd Page 8 of 12
Connect the TSS 440 sub-sea components:
1. Complete the physical installation of the 440 search-coils as described in sub-sec-
tion 3.2.2 of the 440 Manual. Route the coil connection cables to the correct ports
on the 440 SEP. Use plastic cable clips to secure the cables to the fixed frame-
work of the ROV.
2. Install the altimeter near the centre of the 440 search-coil array as described in
sub-section 3.2.3 of this Manual. Route the cable from the altimeter to the 440
SEP and follow the instructions in sub-section 4.1.5.1 of this Manual to connect it.
Use plastic cable clips to secure the cable to the ROV frame.
IMPORTANT
The Dualtrack System uses one altimeter only. You must connect the altimeter to the
ALTIMETER port on the 440 SEP, or to an SDC serial port.
If you connect the altimeter to the ALTIMETER port of the 350 SEP the Dualtrack Sys-
tem will not operate correctly.
3. Connect the 440 SEP to its PSU as described in its Manual.
Connect the TSS 350 sub-sea components:
4. Complete the physical installation of the 350 coil triads as described in sub-sec-
tion 3.2.2 of the 350 Manual. Route the coil connection cables to the correct ports
on the 350 SEP. Use plastic cable clips to secure the cables to the ROV frame-
work.
5. Connect the 350 SEP to the ROV electrical supply by following the instructions in
sub-section 4.2.1 of this Manual.
CAUTION
You might cause permanent damage to the sub-sea installations of the 440 or the 350
System if you operate them from an incorrect electrical supply.
The standard sub-sea components of both Systems operate from a nominal 110V AC
electrical supply. Optionally, both Systems are available for operation from a nominal
240V AC electrical supply.
When you interconnect the 350 and the 350 Systems within a Dualtrack installation,
you must operate both Systems from the same electrical supply.
6. Connect the communications conductors of the 350 Power/Comms cable to the
ROV umbilical. Note that the Dualtrack System would normally use 2-wire current-
loop communications to the SDC to reduce the demand for twisted pairs in the
umbilical. However, where necessary, you may use 4-wire or RS232 communica-
tions instead. Refer to Tables 4–4, 4–5 and 4–6 in this Manual for appropriate
connection details.