6 – Operation software
DPN 402197 © TSS (International) Ltd Page 23 of 32
Figure 6–13: External Output Configuration and Serial Port menu
6.2.2.3 Load Factory Defaults
Selecting this option will present a dialog box. Acceptance of this dialog will result in
the SEP settings being returned to their factory defaults. Certain parameters within
DeepView will also be returned to their default states (see Table 6–5).
6.2.2.4 Video Overlay Setup
The video overlay feature was updated for version 8 SDC. It operates in the similar
way as the previous overlay by receiving a video signal arriving from a user supplied
subsea camera and overlaying it with the DeepView for Windows information speci-
fied by the user via the Video Overlay Configuration. The Video Overlay Setup menu
is available via the Configuration options and provides the options illustrated below in
Figure 6–14.
The video overlay has two possible modes. The first mode is where a copy of the
SDC screen (the Runview) is overlaid on the video output. This is selected with the
"Duplicate Runview" checkbox. The other mode is where selected information, for
example the VRT and target position, are overlaid. The positions and colours of each
of these elements can be fully controlled by the user.
Table 6–5: Factory System Defaults
Parameter Default Value
Tone Frequency Reminder Interval 30 mins
Video Overlay Parameters COM5, 9600, 8, n, 1
External Output Comms Parameters COM3, 9600, 8, n, 1
External Output Packet Coords + signal, 4/second
Altimeter Comms Parameters COM port not specified, 9600, 8, n, 2
Altimeter Type Disabled
Altimeter Offset 0 cm