6.2.4 Using Custom_ASCII to Communicate with an External Device Over Ethernet
To select Custom_ASCII, click on the RCC Protocol pull-down menu, and select Custom_ASCII from the
menu. The protocol configuration for Custom_ASCII is displayed as shown below. The default protocol
configuration parameters are:
Ethernet Socket 1 configured for TCP/IP 20000 as the communications channel
No Frame Start (Command Start) Delimiter — <none>
Carriage Return/Line Feed as Frame End (Command End) Delimiter — \r\n
Comma as the Output Delimiter for the Field Definition — ,
Space as the Input Delimiter for the Field Definition — <SPC>
81Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Tel: 763.544.3164
P/N 000000
System Setup Window Overview7/2009