11
Product Change
This section explains the Product Change (pin 3) input.
The Product Change input is used in conjunction with one of the four I/O points programmed as Product Select lines.
The inspection loaded will be executed following a valid trigger.
The Product Change input responds to the leading edge transition of a pulse greater than 1 millisecond.
The Product Select input is pulsed to correspond to a program location. For example, five pulses will
load program #5.
11.1 Product Change Specifications
Current Sourcing (PNP)Current Sinking (NPN)State
> 8V at -7.5 mA max.< 2V at 1 mA max.ON
< 2V at -7.5 mA max.> 10 V at 4 mA max.OFF
One of the four I/O on the System Setup InputOutput tab must be programmed for Product Select if Product
Change is to be used.
225Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com