2. Use the scroll bar and select an Inspection Number by clicking in the dialog next to the number
where you want to store the inspection, or enter a number in the Inspection Number field.
3. In the Inspection Name field, enter a name for the inspection.
4. Click the Save button in the dialog.
Note: Check the Space Needed and Space Available fields to ensure there is room to save
an inspection. You can choose whether to save a reference image. Not saving a reference image
with the inspection frees up a lot of room onboard the sensor. However, inspections that include
any of the following tools require a reference image to be saved:
Geometric Find
Geometric Count
Pattern Find
Pattern Count
Color Match
Color BLOB
233Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com