Long-Range Ultrasonic Sensors with Electromechanical Relay Output
Teflon-protected Model
Models
Model Sensing
Range
Cable Supply Volt-
age
Operation Mode Output
QT50UVR3W 200 mm to 8
m (8" to 26')
5-wire, 2 m (6.5') cable 85 to 264V ac,
50/60 Hz /48 to
250V dc
Window-limit(N.O.
and N.C.)
SPDT electromechani-
cal relay
QT50UVR3WQ1 5-pin Micro-style QD
QT50UVR3WQ 5-pin Mini-style QD
QT50UVR3F 5-wire, 2 m (6.5') cable Fill-level control
(pump-in and pump-
out)
QT50UVR3FQ1 5-pin Micro-style QD
QT50UVR3FQ 5-pin Mini-style QD
Notes:
9 m cables are available by adding suffix w/30 to the model number of a cabled sensor (for example, QT50UVR3W w/
30).
A model with a QD connector requires a mating cable.
To order a model with Teflon
®
-protected sensor face and transducer, add suffix -CRFV to any model number listed above (for example,
QT50UVR3W-CRFV).
WARNING: Not To Be Used for Personnel Protection
Never use this product as a sensing device for personnel protection. Doing so could lead to serious injury
or death. This product does NOT include the self-checking redundant circuitry necessary to allow its use in
personnel safety applications. A sensor failure or malfunction can cause either an energized or de-ener-
gized sensor output condition.
U-GAGE QT50U Series Sensors
P/N 117764 Rev. E 2/27/2012
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
• Fast, easy-to-use TEACH-Mode programming; no potentiometer adjustments
• SPDT electromechanical relay for high-capacity switching
• Universal supply voltage: 85 to 264V ac / 48 to 250V dc
• Rugged encapsulated design for harsh environments
• Models available with factory-installed Teflon® flange and film coating
bonded over the transducer for protection from harsh environments.
• Unique housing design allows for multiple mounting configurations
• Choose models with integral 2 m (6.5') or 9 m (30') cable, or with Ministyle
or Micro-style quick-disconnect fitting
• Wide operating range of -20° to +70°C (-4° to +158°F)
• Temperature compensation
Teflon® is a registered trademark of Dupont™
Information about dc-voltage models is available on Banner’s website.
Standard Model
Zobrazit stránku 0
1 2 3 4 5 6 ... 11 12

Shrnutí obsahu

Strany 1 - P/N 117764 Rev. E 2/27/2012

Long-Range Ultrasonic Sensors with Electromechanical Relay Output Teflon-protected Model ModelsModel SensingRangeCable Supply Volt-ageOperation Mode

Strany 2 - Temperature Effects

WiringCabled Models QD ModelsNormally Open/Pump-In Normally Open/Pump-In Loadbkyebnbuwh85-264V ac, 50/60 Hz 48-250V dc**shield*Output Current 8A Max.

Strany 3 - Configuration

AccessoriesQuick-Disconnect (QD) CordsetsStyle Model Length Connector Pinouts5-Pin Mini-stylewith shieldMBCC2-506 2 m (6.5') 7/8-16UN-2Bø28 mm(1

Strany 4 - Status Indicators

SAFQT50U• PVC mounting flange mounts to the front of a QT50U sensor (not for use withchemical-resistant models).• Adapts sensor to thread into standar

Strany 5 - Normally Open Output

OverviewUltrasonic sensors excel in position-monitoring applications and in applications involving clear or multi-colored targets.QT50U sensors are av

Strany 6 - Pump-Out Application

Sensor ProgrammingTwo TEACH methods may be used to program the sensor, using the TEACH push button:• Teach individual minimum and maximum limits (see

Strany 7

Enable or Disable Temperature CompensatonPush Button Procedure Result0.04 < "click" < 0.8 sec.Enter ProgrammingModePush and hold the S

Strany 8 - Specifications

Response LED (Yellow or Red) — indicates sensor output response time selection.Response LED Status IndicatesON Red Slow response (1600 ms)ON Yellow Me

Strany 9 - Performance Curves

Pump-In Application(using Normally Open Output)Pump-Out Application(using Normally Closed Output)Initial Tank Level -Outputs are INACTIVELevel Drops B

Strany 10

Teach Second Limit• Without moving the target, "click" the push buttonagain. • Sensor stores sensing window.• Output LED turns ON Yellow.•

Strany 11 - Mounting Brackets

SpecificationsSensing Range200 mm to 8 m (8" to 26')Supply VoltageUniveral Voltage: 85 to 264V ac, 50/60 Hz / 48 to250V dc (1.5 watts maximu

Strany 12

DimensionsCabled Models Chemical-Resistant Models 18 mm (0.71")84.2 mm (3.32")66.0 mm (2.60")37.0 mm(1.46")33.0 mm (1.30")50.